219-LKH Open-loop (Directly Measurement Type) Current Sensor
219-LKH Open-loop (Directly Measurement Type) Current Sensor 219-LKH Open-loop (Directly Measurement Type) Current Sensor 219-LKH Open-loop (Directly Measurement Type) Current Sensor 219-LKH Open-loop (Directly Measurement Type) Current Sensor

219-LKH Open-loop (Directly Measurement Type) Current Sensor

  • Product Detail
  • FAQ
  • Qualification certificate
  • Send Inquiry
PRODUCT OVERVIEW
The sensor works on the principle of direct measurement Hall detection. The magnetic flux generated by the primary current is gathered in the magnetic circuit, and the Hall voltage signal is detected by the Hall device. After amplification by the amplifier, the voltage signal accurately reflects the primary current.
Product Features

Measures AC, DC and pulsed signals

Strong resistance to external interference, high common mode rejection ratio

Low temperature drift, low power consumption, wide frequency band

Perforated structure, no insertion loss

Scope of Application

AC frequency conversion speed regulation

Servo motor traction

Uninterruptible power supply(UPS)

Welding machine, battery power supply

Technical Parameter
Specification 10A/1V 20A/1V 40A/1V Unit
I PN Primary Rated Input Current 10 20 40 A
IP Primary Current Measurement Range 0~20 0~40 0~60 A
VSN Secondary rated output voltage 1 V
VC The Power Supply Voltage ±12~15(±5%) V
IC Current Consumption <20 mA
Vd Insulation Voltage Between primary and secondary circuits:2.5kV/50Hz/1min  
ε L Linearity <1 %FS
X Precision TA=25℃:≤±1 %
V0 Offset Voltage TA =25℃:≤±30 mV
VOM Magnetic Offset Voltage IP =0 after 3*IPN:≤±20 mV
VOT Offset Voltage Temperature Drift I P =0 T A =-25~+75℃:≤±1 mV/℃
Tr Response Time ≤3 μS
f Bandwidth(-3dB ) DC~10 kHZ
TA Working Temperature -25~+75
TS Storage Temperature -45~+85
RL Load Resistance TA =25℃:≥10
Shape and Installation Dimensions
Circuit link diagram

Note:

I PN :Primary current input direction
1 :Positive 12V/15V power supply
2 :Power ground
3 :Secondary signal output
4 :Negative 12V/15V power supply
Installation Precautions

The sensor should be wired correctly, otherwise it may damage the internal components of the sensor

When the sensor is soldered to the circuit board, it needs to be soldered with a low-temperature soldering iron, and the time should not be too long, and secondly, the pins should not be squeezed by a large amount, otherwise the internal connection may be opened.

We are a manufacturer has export qualification and experience.

instrument type at least 100pcs ;others by 1 -5 pcs;

T/T;L/C;

Instrument transformer 20 thousand pcs ;current transformer 12 thousand pcs ;voltage transformer 11 thousand pcs.

We have a R&D team for new product design. Successful cases and in continued cooperation. Discussion among both sides ➡general specification ensure➡structure drawing ➡original sample ➡electrical

Standard Carton Export fumigatin-free tray Tray Film Edge fixing strip Vacuum packaging acceptable Customize size acceptable
Thank you for your message. We will contact you as soon as possible!

Contact Us

Tel:+86-25-84152563

Fax:+86-25-52146294

Email:export@hbtianrui.com

Address:Head Office: No.8 Chuangye Avenue, Economic Development Zone, Tianmen City, Hubei Province, China (Zip Code: 431700) Nanjing Office: Building 23, Baijiahu Science and Technology Industrial Park, No.2 Qingshuiting West Road, Jiangning Economic Development Zone, Nanjing City, Jiangsu Province,China (Zip Code:211106)